Skip to end of metadata
Go to start of metadata

Download PDF Document

2018-05-11

v. 42.1.857


1 Firmware Pack

The firmware pack is a ZIP file that contains the modules and the features to install on your Mediatrix unit when a new release is available.

When unzipping the firmware pack, the content is extracted according to a pre-defined tree architecture. This creates a directory that contains the files required for the Mediatrix unit to properly upgrade its firmware.


2 New Functionalities

Incident # CR # Synopsis Applies To
Description
--- DGW-8324 Add the Image Format parameter for the creation of a virtual machine (VM) Vm

The Image Format parameter allows the user to choose a VM image format when creating a VM image. The new parameter is available in the DGW Web interface under Under/System in the Virtual Machine Creation table. Possible values are:

  • raw which is the default value
  • qcow2
--- DGW-8173 New versioning schematic of DGW 2.0 application. all

The DGW 2.0 application is renamed DGW. Refer to the DGW Software Numbering Convention technical bulletin published on our documentation portal.


3 Modified Features, Functionalities and Interface Modifications

Incident # CR # Synopsis Applies To
Description

IN-13236

DGW-8444 Unable to select the transport protocol in a Call Agent via the DGW Web page when a gateway is selected. Sbc

The configuration of the Force Transport parameter via the Web page for a Call Agent will be enabled at all times.

--- DGW-8324 Add the Image Format parameter for the creation of a virtual machine (VM) Vm

New notification message when more than one VM image shares the same VM name.

IN-13390

DGW-8108 The warning message returned by the set command executed by the SnmpEx.Access.Command is interpreted as an error. Snmp

The SnmpEx.Access.Command (1.3.6.1.4.1.4935.1000.100.200.100.900.1.100.1.100.200.0) now interprets the warning message returned by an executed set command as a success.


4 Issues Fixed

Incident # CR # Synopsis Applies To
Description

IN-13236

DGW-8444 Unable to select the transport protocol in a Call Agent via the DGW Web page when a gateway is selected. Sbc

When a gateway is selected in a Call Agent, the configuration of the Force Transport parameter via the DGW Web page was disabled, now it is enabled.

IN-13390

DGW-8108 The warning message returned by the set command executed by the SnmpEx.Access.Command is interpreted as an error. Snmp

The SnmpEx.Access.Command (1.3.6.1.4.1.4935.1000.100.200.100.900.1.100.1.100.200.0) was interpreting the warning message returned by an executed set command as an error. The warning message is now interpreted as a success and not an error, as it should.

IN-13114

DGW-7051 T.38 fax negotiation through the SBC fails. SBC

T.38 negotiation failed because the INVITEs involved in T.38 represented media transport as UDPTL instead of udptl. Lowercase was corrected, and T.38 fax negotiation no longer fails.


5 Known Issues

Incident # CR # Synopsis Applies To
--- DGW-7027 Unable to download large VM images with some browsers. VM

It is not possible to download large VM images when using some browsers such as Internet Explorer 11.

--- DGW-6795 4124 one-way audio problem on ports 17-24. all

One-way audio problem may happen on 4124 after many days of uptime on ports 17-24.

--- DGW-6455 E1T1 cards configuration is lost after backup restoration. 3000 and Sentinel 400

This problem does not affect units that have never run the DGW 2.0.35 release.

For units running DGW 2.0.35, that have had the DGW 2.0.35 running, or for units that you do not know if the DGW 2.0.35 load was ever installed, use this work around:

IMPORTANT: Before you start, make sure to take a Configuration Script of your complete configuration.

  1. Acces the DGW Web page.
  2. Go to System/Hardware.
  3. For one of the ports, from the *Signaling *drop-down list, select any value. (make sure to remember the value you are changing)
  4. Click Apply.
  5. From the Signaling drop-down list, select the initial value you previously changed.
  6. Click Apply.
  7. Restart the unit.
  8. Take a backup of the configuration.

Result: This will rewrite the persistent configuration of the unit with the proper values.

--- DGW-2457 Downgrading to version DGW 2.0. 37.697 and below causes the DGW application to stop responding and restart. Sentinel 400

Downgrading to GA version DGW 2.0. 37 and below on a Sentinel 400, with analog cards and without a DSP card, causes the DGW application to stop responding and restart. When the DGW application restarts, the Telif service is stopped. For the unit to work properly, you will need to rollback to a DGW software version higher that 2.0.37.697.


6 Copyright Notice

Copyright © 2018 Media5 Corporation.

This document contains information that is proprietary to Media5 Corporation.

Media5 Corporation reserves all rights to this document as well as to the Intellectual Property of the document and the technology and know-how that it includes and represents.

This publication cannot be reproduced, neither in whole nor in part, in any form whatsoever, without written prior approval by Media5 Corporation.

Media5 Corporation reserves the right to revise this publication and make changes at any time and without the obligation to notify any person and/or entity of such revisions and/or changes.