1 Safety Recommendations and Information


1.1 Danger, Warning, Caution, and Note Definitions

Danger

Indicates a hazardous situation which, if not avoided, will result in death or serious injury.

Warning

Indicates a hazardous situation which, if not avoided, could result in death or serious injury.

Caution

Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury or damage to property or equipment.

Note

Indicates important information not related to personal injury.


1.2 Electrical Safety Guidelines

Danger

Do not work on the Mediatrix unit, connect or disconnect its cables during periods of lightning.

Danger

Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of electric shock from lightning.

Danger

Do not connect external lines to Mediatrix S7 units, as it does not have lightning protection.

Warning

The earth ground cable should be the same size (18 AWG minimum) as the earth cable of the provided power cord. Otherwise, make sure the earth ground cable meets the standards and requirements of your local electrical code. The type of the cable is likely to have VW-1 or RT1 markings on the cable.

Warning

The earth ground cable must be firmly and securely connected to the grounding screw on the back of the Mediatrix unit and an appropriate grounding point in your site: the earth ground cable must remain tightly secured at all times during service and installation.

Warning

Disconnect all interface cables (including PRI,BRI,FXS,and FXO) before unplugging any power sources from the Mediatrix unit.

Warning

Disconnect all interface cables (including PRI,BRI,FXS,and FXO) as well as all power sources connected to the Mediatrix unit before servicing the unit.

Warning

This equipment must be installed and maintained by service personnel. Incorrectly connecting this equipment to a general-purpose outlet could be hazardous.

Warning

This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that a fuse or circuit breaker no larger than 120 VAC, 15 A U.S. (240 VAC, 10 A international) is used on the phase conductors (all current-carrying conductors).

Warning

The unit must be grounded at all times when connecting/disconnecting cables.

Warning

The unit must be grounded at all times when in use.

Warning

The earth ground connection between the grounding screw on the back of the Mediatrix unit and an appropriate grounding point in your site must always be made first and disconnected last.

Warning

Do not connect the ETH2, ETH1,LAN, and FXS connectors directly to the Public Switched Telephone Network (PSTN), to an off premise application, an out of plant application, any exposed plant application, or to any equipment other than the intended application, connection may result in a safety hazard, and/or defective operation and/or equipment damage. Exposed plant means where any portion of the circuit is subject to accidental contact with electric lighting or power conductors operating at a voltage exceeding 300 V between conductors or is subject to lightning strikes.

Warning

The Mediatrix unit must be installed on a circuit equipped with a breaker so that you can easily power the unit off if required.

Warning

Hazardous network voltages may be present in PRI and FXO cables. Always disconnect the cables from the Mediatrix unit first to avoid possible electric shock. Network hazardous voltages may be present on the device in the area of the PRI andFXO port, even when power is turned OFF.

Warning

Adequate earth ground connection of the Mediatrix unit is mandatory to avoid any damage or injuries.

Warning

Hazardous network voltages might be present in WAN, LAN, Sync, and telephony port connectors regardless of whether power to the device is OFF or ON. Use caution when working near these connectors to avoid electric shocks.

Warning

The socket outlet, if used, shall be located near the equipment and shall be easily accessible by the user. The AC adaptor inlet is considered as a disconnection device. The device must be readily operational.

Caution

To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cords.

Caution

The RJ-11 cable should comply with UL 1863 and CSA C22.2 No 233 standards.


1.3 General Safety Practices

Warning

Do not use this product near water, for example, near a bath tub, wash bowl, kitchen sink or laundry tub, in a wet basement or near a swimming pool.

Warning

Do not expose the unit to rain or moisture to avoid any shock hazard.

Warning

Do not use the telephone to report a gas leak in the vicinity of the leak.

Warning

Do not get this product wet or pour liquids into it.

Warning

Ultimate disposal of this product should be handled according to all national laws and regulations.

Caution

Unit main become very hot in case of fan failure or during intensive use. To avoid any accidental burns, it is important to restrict the physical access to the unit, and to shut it down for 30 minutes before touching it. In case of fan failure, please contact Media5 or your authorised reseller or vendor.

  • Keep your Mediatrix unit clear and dust-free during and after installation.
  • Locate the emergency power-off switch for the room in which you are working. Then, if an electrical accident occurs, you can act quickly to turn off the power.
  • Do not work alone if potentially hazardous conditions exist.
  • Never assume that power is disconnected from a circuit. Always check.
  • Do not perform any action that creates a potential hazard to people or makes the equipment unsafe.
  • Do not open or disassemble this product.
  • The unit should be located at 20 cm from your monitor, computer casing or other peripheral including speakers.
  • When the unit is brought from a cold to a warm environment, condensation, that might be harmful to the unit, may occur. If this is the case, wait one hour before powering the unit.

1.4 Electrostatic Discharge Prevention

  • When working on a Mediatrix unit, always wear an ESD wrist strap, ensuring that it makes a good contact with your bare skin.
  • Attach the ESD wrist strap end to an earth ground i.e. the grounding screw on the back of the Mediatrix unit or on an unpainted bare metal spot of a grounded equipment rack.
  • Always ensure proper connection between the grounding screw on the back of the Mediatrix unit and an appropriate grounding point in your site to safely channel unwanted ESD to earth ground.

1.5 Translated Warning Definition

Warning

Means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, you must be aware of the hazards involved with electrical circuitry and familiar with standard practices for preventing accidents.

Warning

Dit waarschuwingssymbool betekent gevaar. U overtreat in een situatie die lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij elektrische schakelingen betrokken risico's en dient u op de hoogte te zijn van standaard maatregelen om ongelukken te voorkomen.

Warning

Tämä varoitusmerkki merkitsee vaaraa. Olet tilanteessa, joka voi johtaa ruumiinvammaan. Ennen kuin työskentelet minkään laitteiston parissa, ota selvää sähkökytkentöihin liittyvistä vaaroista ja tavanomaisista onnettomuuksien ehkäisykeinoista.

Warning

Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant causer des blessures ou des dommages corporels. Avant de travailler sur un équipement, soyez conscient des dangers posés par les circuits électriques et familiarisez-vous avec les procédures couramment utilisées pour éviter les accidents.

Warning

Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu einer Körperverletzung führen könnte. Bevor Sie mit der Arbeit an irgendeinem Gerät beginnen, seien Sie sich der mit elektrischen Stromkreisen verbundenen Gefahren und der Standardpraktiken zur Vermeidung von Unfällen bewußt

Warning

Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe causare infortuni alle persone. Prima di lavorare su qualsiasi apparecchiatura, occorre conoscere i pericoli relativi ai circuiti elettrici ed essere al corrente delle pratiche standard per la prevenzione di incidenti.

Warning

Dette varselsymbolet betyr fare. Du befinner deg i en situasjon som kan føre til personskade. Før du utfører arbeid på utstyr, må du vare oppmerksom på de faremomentene som elektriske kretser innebærer, samt gjøre deg kjent med vanlig praksis når det gjelder å unngå ulykker.

Warning

Este símbolo de aviso indica perigo. Encontra-se numa situação que lhe poderá causar danos físicos. Antes de começar a trabalhar com qualquer equipamento, familiarize-se com os perigos relacionados com circuitos eléctricos, e com quaisquer práticas comuns que possam prevenir possíveis acidentes..

Warning

Este símbolo de aviso significa peligro. Existe riesgo para su integridad física. Antes de manipular cualquier equipo, considerar los riesgos que entraña la corriente eléctrica y familiarizarse con los procedimientos estándar de prevención de accidentes.

Warning

Denna varningssymbol signalerar fara. Du befinner dig i en situation som kan leda till personskada. Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanligt förfarande för att förebygga skador.


2 Slot Order - IMPORTANT

The order and location the cards are installed is crucial to the unit to work properly.

  • Slot order is indicated on the front of the unit (left bottom corner)
  • Always start from slot 1
  • No empty slots must be left empty between two cards

Unit with PRI and analog ports

  • All PRI cards must be installed first, starting from slot 1
  • DSP card must be installed in the next available slot
  • Analog cards are installed last

Unit with analog ports only (no PRI ports)

  • DSP card must be installed in slot 1
  • Analog cards are installed last

2.1 Removing a Telephony Card

Before You Start

Warning

When installing or replacing a Telephony Interface Card in the Mediatrix unit, the earth ground connection between the grounding screw on the back of the Mediatrix unit and an appropriate grounding point in your site is mandatory all the time. This is mandatory to avoid any damage or injuries, even if Mediatrix unit is installed in a grounded equipment rack.

Warning

The earth ground cable should be the same size (18 AWG minimum) as the earth cable of the provided power cord. Otherwise, make sure the earth ground cable meets the standards and requirements of your local electrical code. The type of the cable is likely to have VW-1 or RT1 markings on the cable.

Warning

The earth ground cable must be firmly and securely connected to the grounding screw on the back of the Mediatrix unit and an appropriate grounding point in your site: the earth ground cable must remain tightly secured at all times during service and installation.

Warning

Before performing this procedure, you must first read and understand the Safety Recommendations listed in this document.

Warning

The telecommunication lines must be disconnected before unplugging the main power cords.

Warning

This equipment must be installed and maintained by service personnel. Incorrectly connecting this equipment to a general-purpose outlet could be hazardous.

Steps

  1. Make sure an adequate earth ground connection has been made between the grounding screw on the back of the Mediatrix unit and an appropriate grounding point in your site.

    Warning

    Adequate earth ground connection of the Mediatrix unit is mandatory to avoid any damage or injuries.

  2. Wear an ESD wrist strap, ensuring that it makes good contact with bare skin.
  3. Attach the ESD wrist strap end to an earth ground (grounding screw on the back of the Mediatrix unit or unpainted bare metal spot of a grounded equipment rack).
  4. Turn OFF the power switch of the Mediatrix unit.

    Note

    Redundant Power Supply units do not have a power switch.

  5. Turn OFF the power sources used to power the Mediatrix unit at the circuit breaker.
  6. Disconnect all cables (except the earth ground connection) from the Mediatrix unit.

    Caution

    Power source cables must be disconnected last.

  7. Unscrew the two thumb screws of the slot where you wish to remove a card.
  8. Gently remove the existing card.

    Note

    Make sure to reorder the cards so that no slot is left empty between two cards. You can insert any type of card in any of the slots, but you must use the slots from 1 to 8, without leaving slots empty between two cards. Slot order is indicated on the front of the Mediatrix unit (left bottom corner).

    Important

    The only restriction is regarding slot 1:

    • If you have a PRI and a DSP card, the PRI card must be installed in slot 1 and the DSP card must be installed in slot 2.
    • If you have more than one PRI card and a DSP card, all PRI cards must be installed first, starting from slot 1 and the DSP card must be installed in the next available slot.
    • If you have a PRI card, it must be installed in slot 1.
    • If you have a DSP card, it must be installed in slot 1.
    • If you have no DSP or PRI card, all slots (1 to 8) must remain empty.

    Important

    Be aware that if a card is installed and configured to be used in a slot, moving it to another slot will cause the configuration of the slot to be lost. Therefore the card will no longer work until it is reconfigured for the new slot.

  9. Install the blank plate in the slot.
  10. Set the thumb screws back into place. Do not over-tighten.

2.2 Installing a New Telephony Card

Before You Start

Warning

When installing or replacing a Telephony Interface Card in the Mediatrix unit, the earth ground connection between the grounding screw on the back of the Mediatrix unit and an appropriate grounding point in your site is mandatory all the time. This is mandatory to avoid any damage or injuries, even if Mediatrix unit is installed in a grounded equipment rack.

Warning

The earth ground cable should be the same size (18 AWG minimum) as the earth cable of the provided power cord. Otherwise, make sure the earth ground cable meets the standards and requirements of your local electrical code. The type of the cable is likely to have VW-1 or RT1 markings on the cable.

Warning

The earth ground cable must be firmly and securely connected to the grounding screw on the back of the Mediatrix unit and an appropriate grounding point in your site: the earth ground cable must remain tightly secured at all times during service and installation.

Warning

Before performing this procedure, you must first read and understand the Safety Recommendations listed in this document.

Warning

The telecommunication lines must be disconnected before unplugging the main power cords.

Warning

This equipment must be installed and maintained by service personnel. Incorrectly connecting this equipment to a general-purpose outlet could be hazardous.

Important

To comply with the ISED and ACTA regulatory aspects, the label supplied with the telephony card must be applied on the exterior surface of the Model S casing during the installation of the telephony card.

Steps

  1. Make sure an adequate earth ground connection has been made between the grounding screw on the back of the Mediatrix unit and an appropriate grounding point in your site.

    Warning

    Adequate earth ground connection of the Mediatrix unit is mandatory to avoid any damage or injuries.

  2. Wear an ESD wrist strap, ensuring that it makes good contact with bare skin.
  3. Attach the ESD wrist strap end to an earth ground (grounding screw on the back of the Mediatrix unit or unpainted bare metal spot of a grounded equipment rack).
  4. Turn OFF the power switch of the Mediatrix unit.

    Note

    Redundant Power Supply units do not have a power switch.

  5. Turn OFF the power sources used to power the Mediatrix unit at the circuit breaker.
  6. Disconnect all cables (except the earth ground connection) from the Mediatrix unit.

    Caution

    Power source cables must be disconnected last.

  7. Unscrew the two thumb screws of the slot where you wish to install the new card.

    Note

    You can insert any type of card in any of the slots, but you must use the slots from 1 to 8, without leaving slots empty between two cards. Slot order is indicated on the front of the Mediatrix unit (left bottom corner).

    Important

    The only restriction is regarding slot 1:

    • If you have a PRI and a DSP card, the PRI card must be installed in slot 1 and the DSP card must be installed in slot 2.
    • If you have more than one PRI card and a DSP card, All PRI cards must be installed first, starting from slot 1 and the DSP card must be installed in the next available slot.
    • If you have a PRI card, it must be installed in slot 1.
    • If you have a DSP card, it must be installed in slot 1.
    • If you have no DSP or PRI card, all slots (1 to 8) must remain empty.

    Note

    Be aware that if a card is installed and configured to be used in a slot, moving it to another slot will cause the configuration of the slot to be lost. Therefore the card will no longer work until it is reconfigured for the new slot.

  8. Gently remove the blank plate or the existing card.
  9. Gently slide into the internal plastic rails of the slot the new card.
  10. Set the thumb screws back into place. Do not over-tighten.
  11. Apply the label indicating the ISED and ACTA registration numbers on the exterior surface of the casing.

2.3 Replacing a Telephony Card

Before You Start

Warning

When installing or replacing a Telephony Interface Card in the Mediatrix unit, the earth ground connection between the grounding screw on the back of the Mediatrix unit and an appropriate grounding point in your site is mandatory all the time. This is mandatory to avoid any damage or injuries, even if Mediatrix unit is installed in a grounded equipment rack.

Warning

The earth ground cable should be the same size (18 AWG minimum) as the earth cable of the provided power cord. Otherwise, make sure the earth ground cable meets the standards and requirements of your local electrical code. The type of the cable is likely to have VW-1 or RT1 markings on the cable.

Warning

The earth ground cable must be firmly and securely connected to the grounding screw on the back of the Mediatrix unit and an appropriate grounding point in your site: the earth ground cable must remain tightly secured at all times during service and installation.

Warning

Before performing this procedure, you must first read and understand the Safety Recommendations listed in this document.

Warning

The telecommunication lines must be disconnected before unplugging the main power cords.

Warning

This equipment must be installed and maintained by service personnel. Incorrectly connecting this equipment to a general-purpose outlet could be hazardous.

Steps

  1. Make sure an adequate earth ground connection has been made between the grounding screw on the back of the Mediatrix unit and an appropriate grounding point in your site.

    Warning

    Adequate earth ground connection of the Mediatrix unit is mandatory to avoid any damage or injuries.

  2. Wear an ESD wrist strap, ensuring that it makes good contact with bare skin.
  3. Attach the ESD wrist strap end to an earth ground (grounding screw on the back of the Mediatrix unit or unpainted bare metal spot of a grounded equipment rack).
  4. Turn OFF the power switch of the Mediatrix unit.

    Note

    Redundant Power Supply units do not have a power switch.

  5. Turn OFF the power sources used to power the Mediatrix unit at the circuit breaker.
  6. Disconnect all cables (except the earth ground connection) from the Mediatrix unit.

    Caution

    Power source cables must be disconnected last.

  7. Unscrew the two thumb screws of the slot where you wish to change the card.
  8. Gently remove the installed card.
  9. Gently slide into the internal plastic rails of the slot the new card.
  10. Set the thumb screws back into place. Do not over-tighten.

3 Product Disposal Instructions

This symbol indicates that the product is classified as electrical or electronic equipment and should not be disposed of along with commercial or household waste at the end of its working life. For appropriate disposal and recycling instructions, contact your local Media5 Corporation provider.
The Waste of Electrical and Electronic Equipment (WEEE) Directive (2002/96/EC) was established by the European Union to minimize negative impact on the environment, control hazardous substances, and curtail landfill expansion by using the best available recovery and recycling techniques.


4 Disclaimers

Federal Communications Commission (FCC)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Note

This equipment has been tested and found to comply with the limits for a Class BAdigital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/television technician for help.

Important

Any modifications made to this device that are not approved by Media5 Corporation may void the authority granted to the user by the FCC to operate this equipment.

Innovation, Science and Economic Development Canada (ISED)

This Class BA digital apparatus complies with Canadian ICES-003.

CE Marking

DECLARATION OF CONFORMITY
We, Media5 Corporation, located at 4229 Garlock st. Sherbrooke, Québec, Canada J1L 2C8, declare that for the hereinafter mentioned product the presumption of conformity with the applicable essential requirements of Directives 2014/30/EC and 2014/35/EC European parliament (EMC and LVD directives)is given. Any unauthorized modification of the product voids this declaration. For a copy of the original signed Declaration Of Conformity please contact Media5 at the above address.

RoHS Declaration Of Compliance

This Mediatrix unit is in compliance with the Council Directives 2011/65/EC on the restriction of the use of certain hazardous substances in electrical and electronic equipment.

RoHS China

Model M complies with the China IEC 60950-1 safety deviation, but does not have CCC approvals.

Altitude of Operation

Use only at altitudes no more than 2000 m above sea level.
Only use in non-tropical climate regions.

5 Available Documentation

For more details, refer to the Mediatrix Documentation .

6 Copyright Notice

Copyright © 2018 Media5 Corporation.

This document contains information that is proprietary to Media5 Corporation.

Media5 Corporation reserves all rights to this document as well as to the Intellectual Property of the document and the technology and know-how that it includes and represents.

This publication cannot be reproduced, neither in whole nor in part, in any form whatsoever, without written prior approval by Media5 Corporation.

Media5 Corporation reserves the right to revise this publication and make changes at any time and without the obligation to notify any person and/or entity of such revisions and/or changes.