Available DGW Firmware Versions
Incident # | CR # | Synopsis | Applies To |
---|---|---|---|
Description | |||
IN 11529 |
DGW-3684 | Create new profile for Mediatrix 4102S, Mediatrix C710, and Mediatrix C711 units. | Mediatrix 4102S, Mediatrix C710, and Mediatrix C711 |
A new profile for Mediatrix 4102S, Mediatrix C710, and Mediatrix C711 units was created. |
|||
IN 11879 |
DGW-3354 | Create new BN profile. | Mediatrix 4102/4116 |
A new BN profile for 4102 units was created. |
|||
IN 11879 |
DGW-3353 | Create new MB profile. | Mediatrix 4102/4116 |
A new MB profile for 4102 and 4116 units was created. |
|||
IN11879 |
DGW-3352 | Create new SB profile | Mediatrix 4102/4116 |
A new SB profile for 4102 and 4116 units was created. |
|||
--- | DGW-2854 | Add the PersistentWearPercentage status scalar. | all |
The new PersistentWearPercentage status scalar under Dcm->Statistics->Memory gives an estimation of the wear level of the persistence on the unit. A wear level of 100 indicates that the unit should be expected to start failing because of the wear. On units without a persistence that can be measured, the scalar returns -1. |
|||
--- | DGW-2270 | Add TR-069 ACS tone customisation. | all |
Tone customisation is now possible on TR-069 API Control Services (ACS). |
|||
--- | DGW-2268 | Add parameter to allow the TR-069 ACS to reset the SIP user-agent. | all |
The VoiceService{i}.VoiceProfile{i}.Reset TR-104 parameter in CWMP service was added to force all the lines of a profile to be reset, causing the SipEp service to be re-initialised and perform all start-up actions on endpoints. |
|||
IN-11370 |
DGW-2262 | Add fallback SNTP server list when not provisioned by DHCP. | all |
A new "AutomaticWithFallback" option for the SNTP configuration was added. This option does a fallback to the StaticSntpServers table when no SNTP servers are automatically obtained from the IPv4 network. |
|||
IN 11653 |
DGW-1489 | Allow the integration of Dgw with the 3rd party Redirection and Provisioning Server. | all |
The following three new features were added to allow the integration of Dgw to the 3rd party Redirection and Provisioning Server:
|
|||
DGW-1299 | DGW application needs support of Mediatrix G7 1-2-4 PRI. | all | |
Added the full support of the Mediatrix G7 with 1-2-4 PRI interfaces. |
|||
--- | DGW-1087 | Add the support of the reception of hook flash events in SIP INFO messages. | all |
The reception of hook flash events is now supported in SIP INFO messages when the DTMF transport method is set to InfoDtmfRelay. Upon reception of a hook flash event, a hook flash is executed on the telephony interface, if the telephony interface supports it. |
Incident # | CR # | Synopsis | Applies To |
---|---|---|---|
Description | |||
--- | DGW-2270 | Add TR-069 ACS tone customisation. | all |
New parameters were added to support the tone customisation of the TR-069 ACS:
|
|||
--- | DGW-2268 | Add parameter to allow the TR-069 ACS to reset the SIP user-agent. | all |
The VoiceService{i}.VoiceProfile{i}.Reset TR-104 parameter is now supported in CWMP service allowing to chose to force all the lines of a profile to be reset, causing the SipEp service to be re-initialised and perform all start-up actions on endpoints. |
|||
IN-11370 |
DGW-2262 | Add fallback SNTP server list when not provisioned by DHCP. | all |
The new "AutomaticWithFallback" option was added to configure the SNTP configuration source. |
|||
DGW-1625 | Clock reference does not work on Sentinel units. | Sentinel | |
The following new parameters were implemented in the Web page.:
The following parameters / table were deleted:
|
|||
--- | DGW-1503 | The ApaSip component does not start when the Domain Name Source is set to "Automatic IPv6". | Sentinel |
The Hoc service now accepts a list of several items of the dhcp6.domain-search domain-list option. |
|||
IN 11653 |
DGW-1489 | Allow the integration of Dgw with the 3rd party Redirection and Provisioning Server. | all |
The following three new features were added to allow the integration of Dgw to the 3rd party Redirection and Provisioning Server:
|
Incident # | CR # | Synopsis | Applies To |
---|---|---|---|
Description | |||
DGW-4473 | The Mediatrix Sentinel 400 may restart when targeted by a specific SQL injection attack in SIP. | Sentinel 400 | |
An issue in the logging subsystem has been identified and corrected.The SBC logging subsystem no longer triggers the Sentinel to be restarted. |
|||
DGW-4237 | The Mediatrix G7 unit Power LED is not turned on. | G7 | |
The Dgw software was corrected to properly light the power LED of the Mediatrix G7 unit. |
|||
--- | DGW-3845 | The Media tab in the Dgw Web interface is displayed with a cardless Sentinel. | Sentinel |
When the Sentinel has no cards, the Media tab in the Dgw Web interface is no longer available. |
|||
--- | DGW-3608 | Modify a custom profile to better support configuration server URLs. | all |
Modify the profile according to the customer's request. |
|||
--- | DGW-3607 | PRI cards configuration is not properly converted or restored. | all |
While upgrading from DGW 2.0.34, or older, to DGW 2.0.35, the PRI cards configuration is not converted and the default values are instead applied. |
|||
IN 12130 |
DGW-3458 | The watchdog does not restart the unit if the watchdog event is triggered during an SSD access. | Sentinel |
The watchdog now restarts the unit if the watchdog event is triggered during an SSD access. The watchdog was changed to generate a pulse instead of using a level mode, as configured in the BIOS. When the watchdog event is triggered, a signal is also generated on the PSOK pin. |
|||
--- | DGW-3163 | The Passive notification for the NetworkInterfacesStatus.DefaultRouter columnar is not functional. | all |
When the value of the NetworkInterfacesStatus.DefaultRouter columnar will be changed, the unit will notify the Acs in the next "Inform" to update the value. |
|||
--- | DGW-3051 | Add the support for the detection of a tone with 4 pairs of ON/OFF times. | all |
The Fxo.FxoForceEndOfCallToneCustomSettingsGroup.FxoFeocToneCustomCadence parameter was modified to support up to 4 pairs of ON/OFF times instead of 3. |
|||
--- | DGW-2569 | Unable to change the "Call agent based on R-URI" route type to the "Static Route" route type. | Sbc |
The user could not modifying the "Call agent based on R-URI" route type of a Routing Ruleset to "Static Route". This has been fixed. |
|||
IN 11915 |
DGW-2531 | Transfer fails when using inband ringback. | Sbc Service |
When a call was transferred with inband ringback, the To-tag was changed by the PBX. The default behavior was to use the old To-tag when transferring the call. However, some PBXs would expect the transfer to use the newer To-tag. The "Enable transparent dialog IDs" call agent rule was modified to offer 2 options :
|
|||
IN 11370 |
DGW-2405 | Unable to automatically execute the configuration scripts. | all |
When using HTTPS provisioning, the automatic execution of the configuration failed because the time on the unit was not synchronised with the time server. Therefore, when establishing the HTTPS connection, the required certificates were considered invalid. Time synchronisation is now granted more time, therefore the connection to the HTTPS server can be established allowing the automatic execution of the configuration scripts. |
|||
IN 11893 |
DGW-2368 | SIP calls not supported if the media transport is changed during SDP negotiation. | all |
Changing the media transport from RTP to SRTP or SRTP to RTP during the SDP negotiation of a SIP call is now allowed until a reliable answer is received, i.e. the 200 Ok of the INVITE or a reliable provisional response with PRACK. |
|||
--- | DGW-2357 | Importing Ruleset files with names longer than 48 characters causes various issues. | Sbc service |
It was possible to import Ruleset files with names longer than 48 characters, which was causing the following issues in the Web pages of the Sbc service:
Importing Ruleset files with names longer than 48 characters is now forbidden. Importation is also forbidden if the file extension is incorrect or if the filename contains unauthorized characters. To address the case where Rulesets with names too long were already present in a unit, a few changes were made to the Web pages:
|
|||
IN 11817 |
DGW-2017 | Unable to use for the virtual machine one MAC address for the LAN and another MAC address for the WAN. | VM |
The virtual machine can now use two different MAC addresses, one for the LAN and one for the WAN. |
|||
DGW-1625 | Clock reference does not work on Sentinel units. | Sentinel | |
The clock reference mechanism was updated on the Mediatrix Sentinel units. The new mechanism is common to all supported platforms, and previous mechanisms were removed. |
|||
--- | DGW-1503 | The ApaSip component does not start when the Domain Name Source is set to "Automatic IPv6". | Sentinel |
When the Domain Name Source is set to "Automatic IPv6" and the DHCP server IPv6 returns a list of several domains in the dhcp6.domain-search option domain-list, the Hoc service sets this list as a single name in the system. This prevented the internal DHCP server to start correctly, causing the telephony cards (IP based in Sentinel) to fail starting also. The Hoc service now uses the first valid domain name from the list and sets it in the system. |
Incident # | CR # | Synopsis | Applies To |
---|
Copyright © 2020 Media5 Corporation.
This document contains information that is proprietary to Media5 Corporation.
Media5 Corporation reserves all rights to this document as well as to the Intellectual Property of the document and the technology and know-how that it includes and represents.
This publication cannot be reproduced, neither in whole nor in part, in any form whatsoever, without written prior approval by Media5 Corporation.
Media5 Corporation reserves the right to revise this publication and make changes at any time and without the obligation to notify any person and/or entity of such revisions and/or changes.