Incident # | CR # | Synopsis | Applies To |
---|---|---|---|
Description | |||
IN 12159 | DGW-3820 | Add an option to automatically switch to the first caller when a second caller hangs up. | FXS ports |
During a call with a second peer (second call), when a SIP BYE is sent by the peer, two behaviors can occur depending on the value of the new EpServ.DefaultSecondCallDisconnectAction and EpServ.EpSpecificSecondCallTable.DisconnectAction parameters. If the parameters are set to
| |||
--- | DGW-3234 | Add CWMP support for voice/data codecs parameters. | all |
Add CWMP parameters for all supported voice/data codecs which include G.711 a-Law, G.711 u-Law, G.726 16Kbps, G.726 24Kbps, G.726 32Kbps, G.726 40Kbps, G.729, T.38, clear mode, clear channel and X-CCD. | |||
--- | DGW-2528 | Allow the administrator to remotely configure a subset of the telephony services with TR-069. | all |
The CWMP parameters for hold, call waiting, second call, transfer, conference, forward telephony services, and DTMF map configuration were added. | |||
IN 11370 | DGW-2169 | Support for a single file firmware upgrade. | Firmware upgrade |
It is possible to update the unit using a single file upgrade download. The multiple file firmware download is still possible. |
Incident # | CR # | Synopsis | Applies To |
---|---|---|---|
Description | |||
DGW-4198 | Parameters used to configure multiple file transfer for firmware upgrades are now deprecated. | all | |
The following parameters used to configure multiple file transfer for firmware upgrades are now deprecated:
The parameter Fpu.MfpUrl used to configure single file updates for firmware upgrades should be used instead. | |||
--- | DGW-3060 | Bandwidth control is not available on the Mediatrix Sentinel 400. | Sentinel 400 |
Bandwidth control is now available on the Mediatrix Sentinel 400. | |||
IN 11370 | DGW-2169 | Support for a single file firmware upgrade. | Firmware upgrade |
We have modified the MIBs, Web pages to add the support for single file upgrade download. | |||
--- | DGW-3234 | Add CWMP support for voice/data codecs parameters. | all |
All parameters under Mipt.Codec group are supported in CWMP. | |||
--- | DGW-2528 | Allow the administrator to remotely configure a subset of the telephony services with TR-069. | all |
The parameters under the following groups are now supported in CWMP:
| |||
DGW-1258 | The SBC Number of Active Calls parameter is not yet supported. | Sbc service | |
The Sbc.NbActiveCalls parameter is now supported. |
Incident # | CR # | Synopsis | Applies To |
---|---|---|---|
Description | |||
DGW-4489 | Fix memory leak upon reception of HTTP requests. | all | |
Fix memory leak upon reception of HTTP requests. | |||
DGW-4481 | DHCP client memory leak when sending DHCP inform. | all | |
Fixed memory leak in DHCP client. | |||
DGW-4198 | Parameters used to configure multiple file transfer for firmware upgrades are now deprecated. | all | |
Single file update is now supported by DGW for firware upgrade. Parameters used to configure multiple file transfer for firmware upgrades are now deprecated. The parameter used to configure single file updates for firmware upgrades should be used instead. | |||
DGW-3994 | All interfaces have the same physical address in the SNMP's IfTable. | all | |
SNMP's IfTable now contains the proper physical address for each interface of the unit. | |||
DGW-3964 | The "Cancel Sensing" button does not work. | ISDN and EAM | |
Using the "Cancel Sensing" button in the ISDN/Status and EAM/Status Web pages had no effect. The "Cancel Sensing" button in the "Automatic Configuration" group of the ISDN/Status and EAM/Status Web pages is now enabled. | |||
DGW-3939 | Unable to change the clock reference source from Slot3/E1T1 to Slot2/E1T1. | all | |
It was not possible to change the clock reference directly from Slot3/E1T1 to Slot2/E1T1. An intermediary setting had to be used to make it work. For example, from Slot3/E1T1 to none then from none to Slot2/E1T1. It is now possible to directly change the clock reference from Slot3/E1T1 to Slot2/E1T1. | |||
IN 12298 | DGW-3927 | Subnets larger than 24 are not used by the DHCP service. | DHCP service |
If the DHCP server on the Mediatrix gateway was activated and configured with a subnet that is larger than 24, it would revert back to 24 when validating the range. Therefore, only the first 256 addresses from a subnet where usable in the range, even when the subnet was larger. Subnets larger that 24 are now handled properly by the DHCP service. | |||
IN 12283 | DGW-3901 | The FXO port sometimes stops working on the Sentinel. | Sentinel |
On an incoming call, the Sentinel FXO port did not always detect the ring and would not answer the call until the Pots service was restarted. The FXO port now properly detects the ring. The interrupt controller was fixed to prevent interruption losses that caused the FXO port to stop working. | |||
IN 12272 | DGW-3873 | TAC traces were published in the CLI only if a remote host was set. | all |
TAC traces will now be published provided that they are enabled in Nlm service and that either the value for the Remote Host is not empty or that CLI logs are enabled. | |||
--- | DGW-3060 | Bandwidth control is not available on the Mediatrix Sentinel 400. | Sentinel 400 |
The system installed on the unit needed an additional module to support bandwidth control. This module was added. | |||
--- | DGW-2643 | Unit uses locally configured network policies instead of applying the received policies. | all |
The unit sometimes fell in a state where it ignored the received LLDP-MED packets until the unit was restarted. The unit would therefore use locally configured network policies instead of applying the received policies. The restart logic of the LLDP service was fixed to accept LLDP-MED packets when a service is restarted. | |||
IN 10280 | DGW-2015 | System closes unexpectedly when a change requires the SipEp service to be restarted and the registration to be refreshed. | CWMP |
Receiving a command from the ACS that contains a change that requires to restart the SipEp service and to refresh the registration no longer causes the system to close unexpectedly. | |||
DGW-1258 | The SBC Number of Active Calls parameter is not yet supported. | Sbc service | |
The SBC Number of Active Calls parameter is now supported. |
Incident # | CR # | Synopsis | Applies To |
---|---|---|---|
DGW-5330 | Remote peers reject calls because of an "Unsupported type Media" error. | SBC | |
In a SIP authentication scenario, the Sbc changes SRTP to RTP causing the remote peer to reject calls because of an "Unsupported type Media" error. | |||
--- | DGW-3341 | Running Config page is empty after downgrading the Dgw software from version 35.657. | Sbc service |
After downgrading the Dgw software from version 35.657 to a previous version, the "Running Config" page is empty. This is caused by the "Reset dialog by 1xx replies" Ruleset action. Before downgrading, delete the "Reset dialog by 1xx replies" Ruleset action. |
Copyright © 2016 Media5 Corporation.
This document contains information that is proprietary to Media5 Corporation.
Media5 Corporation reserves all rights to this document as well as to the Intellectual Property of the document and the technology and know-how that it includes and represents.
This publication cannot be reproduced, neither in whole nor in part, in any form whatsoever, without written prior approval by Media5 Corporation.
Media5 Corporation reserves the right to revise this publication and make changes at any time and without the obligation to notify any person and/or entity of such revisions and/or changes.