Available DGW Firmware Versions
Incident # | CR # | Synopsis | Applies To |
---|---|---|---|
Description | |||
DGW-5665 | Create the new Mediatrix S7 series for the future replacement of the Mediatrix 4116/4124 | all | |
The new Mediatrix S7 series and Mediatrix S7 LP series are now available in replacement of the Mediatrix 4116/4124 units and Mediatrix 4116/4124 LP units. The Mediatrix supports up to 24 FXS ports. |
|||
--- | DGW-4651 | Mediatrix G7 Series and Sentinel 100 must support the 4-FXS and 4-FXO cards. | FXS |
The 4-FXS and the 4-FXO cards are now supported on the Mediatrix G7 Series and Sentinel 100. |
|||
— |
DGW-3572 | Add new packet capture options for remote troubleshooting. | all |
Packet capture functionality was added in the NLM service, allowing captured packets to be sent to a file in the File service or transferred in real time via a PUT to a HTTP server. This packet capture can be used from all configuration interfaces with the exception of TR-069. The packet capture uses the new following parameters and commands:
The packet capture can be configured via the Web interface, under the System/Packet Capture tab. |
|||
--- | DGW-3472 | Allows loading a MOH music file from the local file system. | all |
It is now possible to transfer a mp3 file for MOH using the file service. The mp3 file must be imported on the unit via the file service, with the "Path" or "Destination" set to "moh/". Then, in the "Music on Hold" configuration page, "file://filename.mp3" will be accepted has a valid URL. |
Incident # | CR # | Synopsis | Applies To |
---|---|---|---|
Description | |||
— |
DGW-3981 | Syntax of the Nlm.SyslogRemoteHost parameter not validated. | Nlm |
The syntax of Nlm.SyslogRemoteHost is now validated when a new value is set via the Web page, the Cli, Snmp, or a configuration script. The upgrade and restore functionalities are not affected by this validation. |
|||
— |
DGW-3572 | Add new packet capture options for remote troubleshooting. | all |
The packet capture can be configured via the Web interface, under the System/Packet Capture tab. The packet capture uses the new following parameters and commands:
|
|||
--- | DGW-3472 | Allows loading a MOH music file from the local file system. | all |
It is now possible to transfer a mp3 file for MOH using the file service. |
Incident # | CR # | Synopsis | Applies To |
---|---|---|---|
Description | |||
--- | DGW-6418 | Mediatrix 4108/16/24 and LP16/24 units become unreachable when bridging is used. | 4108/16/24 , LP16, LP24 |
When the Mediatrix 4108/16/24 and LP16/24 units are configured to bridge two Ethernet ports, the unit no longer becomes unreachable. |
|||
— |
DGW-6311 | Received Reinvites with the same CSeq used in the Invite causes one way audio or call failures. | Sbc |
If the Sbc receives a Reinvite using the same CSeq as the one of the Invite it sent, it no longer causes one way audio or call failures. |
|||
— |
DGW-6238 | PCM captures are sent to different UDP port numbers. | all |
The PCM captures were sent to UDP port numbers 5000+X and 6000+X, where X was the channel number. Now they are always sent to ports 5001 and 6001. |
|||
— |
DGW-6197 | Ciphers are not listed by Sbc in the proper order. | SBC |
The order of the ciphers was no longer from most secure to less. This was corrected. |
|||
— |
DGW-6196 | Cipher AES_256_CM_HMAC_SHA1_80 is ignored by the SBC. | SBC |
When offered a AES_256_CM_HMAC_SHA1_80 in SRTP, the SBC no longer ignores it. |
|||
IN-12876 |
DGW-6135 | Link to Date/Time Criteria Editor not working. | all |
The link to the "Date/Time Criteria Editor" page available in the Transformation Rule editor Web page has been restored. |
|||
— |
DGW-5391 | Mediatrix 3XXX series units sometimes close unexpectedly after an update. | all |
Mediatrix 3XXX Series units no longer close unexpectedly after an update. |
|||
— |
DGW-5073 | Configuration script not working properly for subnet settings. | Dhcp |
The subnet settings in the DHCP configuration are no longer incorrectly exported using the configuration script. |
|||
— |
DGW-5033 | The %capubip% macro used in a Registration Agent contact creates a Contact containing a port specified as ":0" | SBC |
When the Sbc.RegistrationAgent.Contact parameter was configured with the %capubip% macro while the corresponding port was set to 0 in the Sbc.SignalingInterface table, the REGISTER request was sent with a Contact containing a port specified as ":0" . In this case, the Contact is now created without a port . |
|||
— |
DGW-3981 | Syntax of the Nlm.SyslogRemoteHost parameter not validated. | Nlm |
The syntax of the Nlm.SyslogRemoteHost parameter is now validated when a new value is set via the Web page, the Cli, Snmp, or a configuration script. The upgrade and restore functionalities are not affected by this validation. |
|||
--- | DGW-3341 | Running Config page is empty after downgrading the Dgw software from version 35.657. | Sbc service |
After downgrading the Dgw software from version 35.657 to a previous version, the "Running Config" page is no longer empty. |
Incident # | CR # | Synopsis | Applies To |
---|
Copyright © 2020 Media5 Corporation.
This document contains information that is proprietary to Media5 Corporation.
Media5 Corporation reserves all rights to this document as well as to the Intellectual Property of the document and the technology and know-how that it includes and represents.
This publication cannot be reproduced, neither in whole nor in part, in any form whatsoever, without written prior approval by Media5 Corporation.
Media5 Corporation reserves the right to revise this publication and make changes at any time and without the obligation to notify any person and/or entity of such revisions and/or changes.