<html lang="en"><head><meta http-equiv="Content-Type" content="text/html; charset=UTF-8"><meta charset="UTF-8"><meta name="copyright" content="(C) Copyright 20222023"><meta name="DC.rights.owner" content="(C) Copyright 20222023"><meta name="DC.type" content="concept"><meta name="description" content="A clock reference is needed to synchronise the PRI or BRI frames."><meta name="prodname" content="Mediatrix units with ONLY 2 Ethernet ports"><meta name="version" content="DGW 49.01.28092884"><meta name="platform" content="All"><meta name="DC.date.modified" content="20222023-1103-1028"><meta name="DC.date.issued" content="20222023-1103-1028"><meta name="DC.date.available" content="20222023-1103-1028"><meta name="ChapterNumbering" content="no"><meta name="DC.format" content="HTML5"><meta name="DC.identifier" content="concept_an5_cdb_ww"><link href="https://fonts.googleapis.com/css?family=Open+Sans" rel="stylesheet"><link rel="stylesheet" type="text/css" href="https://documentation.media5corp.com/download/attachments/62825785/commonltr.css"><link rel="stylesheet" type="text/css" href="https://documentation.media5corp.com/download/attachments/62825785/custom.css"><title>Hardware Configuration User Guide</title></head><body><header role="banner"><div class="topicmeta title">Hardware Configuration User Guide</div><div class="topicmeta date">2022>2023-1103-10<28</div><div class="topicmeta product">Mediatrix units with ONLY 2 Ethernet ports</div><div class="topicmeta version">DGW 49.01.2809<2884</div><div class="topicmeta pdf"><a href="https://documentation.media5corp.com/download/attachments/62825785/Hardware%20Configuration%20User%20Guide.pdf" rel="nofollow">Download PDF Document</a></div><hr><span style="float: inline-end;"></span></header><nav role="toc"><ul><li><a href="#concept_an5_cdb_ww">Clock Reference</a><ul><li><a href="#task_qw3_4fb_ww">Setting the Clock Reference </a></li><li><a href="#task_y2m_1cb_ww">Setting Fallback Clock Reference Sources</a></li></ul></li><li><a href="#topic_title_PRI_BRI_Card_Configuration_d1e18">PRI/BRI Card Configuration</a><ul><li><a href="#task_p1v_ysc_ww">Associating a PRI Port to a Line Type and Protocol</a></li><li><a href="#unique_18643365261779074839">Associating a BRI Port to a Line Type and Protocol</a></li></ul></li><li><a href="#topic_title_Power_Feeding_d1e21">Power Feeding</a><ul><li><a href="#task_bkp_2jb_ww">Enabling Power Feeding</a></li><li><a href="#unique_925622820785344014">Disabling Power Feeding</a></li></ul></li><li><a href="#topic_title_Bridging_d1e24">Bridging</a><ul><li><a href="#task_uhd_4kb_ww">Bridging two Ethernet Ports</a></li><li><a href="#task_w3c_wrb_ww">Creating the Bridging Interface</a></li></ul></li><li><a href="#reference_gs4_rxw_ww">Hardware Advanced Parameters </a></li><li><a href="#reference_j4g_nbv_gfb">Online Help</a></li><li><a href="#concept_v4k_q3h_1r">DGW Documentation</a></li><li><a href="#concept_fqm_rv4_k4">Copyright Notice</a></li></ul></nav><main role="main"><article role="article" aria-labelledby="ariaid-title1"><hr><span style="float: inline-end;"><a href="#">Top</a></span><article class="nested0" aria-labelledby="ariaid-title1" id="concept_an5_cdb_ww">
<h1 class="title topictitle1" id="ariaid-title1">Clock Reference</h1>
<div class="body conbody"><p class="shortdesc">A clock reference is needed to synchronise the PRI or BRI frames.</p>
<p class="p">If the clock reference is not configured according to the network environment, the clock will
slip and voice quality may degrade.</p>
<p class="p">The clock reference can be generated internally or obtained from an external source (e.g., PRI
or BRI telephony provider). If you have an interface connected to a PRI or BRI telephony
provider, the clock reference must be selected from the DGW Web interface. The clock reference
provides error-free data and fax transmission. The clock reference may either be provided by the
network or by one of the BRI, PRI, or Sync port of the Mediatrix unit. </p>
<p class="p">The Mediatrix 3000 has a TDM for each card. Therefore, each extension card can be configured to
use a different source for the Clock Reference. This means that depending on the telephony ports
being used, up to two Clock Reference sources can be used simultaneously on the Mediatrix 3000
Series units. All other Mediatrix units have only one TDM, therefore only one source for the
Clock Reference can be used at a time. Fallback can however be configured on all Mediatrix units
with a PRI, BRI, or external Sync port, since in this case, only one Clock Reference source can
be used at a time. </p>
</div>
<hr><span style="float: inline-end;"><a href="#">Top</a></span><article class="topic task nested1" aria-labelledby="ariaid-title2" id="task_qw3_4fb_ww">
<h2 class="title topictitle2" id="ariaid-title2">Setting the Clock Reference </h2>
<div class="body taskbody">
<section class="section context"><div class="tasklabel"><strong class="sectiontitle tasklabel">Context</strong></div>
<div class="note important note_important"><span class="note__title">IMPORTANT:</span> This feature is only available on Mediatrix units with PRI, BRI,
or external Sync ports.</div>
</section>
<section><div class="tasklabel"><strong class="sectiontitle tasklabel">Steps</strong></div><ol class="ol steps"><li class="li step">
<span class="ph cmd">Go to <span class="keyword wintitle">System</span>/<span class="keyword wintitle">Hardware</span>.</span>
</li><li class="li step">
<span class="ph cmd">From the <span class="keyword wintitle">Clock Reference
Configuration</span>
table, select from the <span class="keyword wintitle">Suggestion</span> list, one clock
reference source.</span>
</li><li class="li step">
<span class="ph cmd">Click <span class="keyword wintitle">Apply</span>.</span>
</li></ol></section>
<section class="section result"><div class="tasklabel"><strong class="sectiontitle tasklabel">Result</strong></div>The clock reference source is displayed in the <span class="keyword wintitle">Value</span> field of the <span class="keyword wintitle">Clock Reference
Configuration</span> table.
If the source is unavailable, the unit will remain operational, however, audio quality
may be altered and data transmission may not be accurate. This is an example of the Web
page on a Sentinel.<br><img class="image" id="task_qw3_4fb_ww__image_l1n_hty_zw" src="https://documentation.media5corp.com/download/attachments/62825785/ClockReferenceConfiguration.png" width="800"><br></section>
</div>
</article><hr><span style="float: inline-end;"><a href="#">Top</a></span><article class="topic task nested1" aria-labelledby="ariaid-title3" id="task_y2m_1cb_ww">
<h2 class="title topictitle2" id="ariaid-title3">Setting Fallback Clock Reference Sources</h2>
<div class="body taskbody">
<section class="section context"><div class="tasklabel"><strong class="sectiontitle tasklabel">Context</strong></div><div class="note important note_important"><span class="note__title">IMPORTANT:</span> This feature is only available on Mediatrix units with PRI, BRI, or
external Sync ports.</div></section>
<section><div class="tasklabel"><strong class="sectiontitle tasklabel">Steps</strong></div><ol class="ol steps"><li class="li step">
<span class="ph cmd">Go to <span class="keyword wintitle">System</span>/<span class="keyword wintitle">Hardware</span>.</span>
</li><li class="li step">
<span class="ph cmd">From the <span class="keyword wintitle">Clock Reference
Configuration</span>
table, select from the <span class="keyword wintitle">Suggestion</span> list, several
clock reference sources.</span>
</li><li class="li step">
<span class="ph cmd">Click <span class="keyword wintitle">Apply</span>.</span>
</li></ol></section>
<section class="section result"><div class="tasklabel"><strong class="sectiontitle tasklabel">Result</strong></div>The clock reference sources are displayed in the <span class="keyword wintitle">Value</span> field of the <span class="keyword wintitle">Clock Reference
Configuration</span> table.
When the first source is unavailable, the second source is used, and so on. If no source
is available, the unit will remain operational, however, audio quality may be altered
and data transmission may not be accurate. <br><img class="image" id="task_y2m_1cb_ww__image_rz3_ccz_zw" src="https://documentation.media5corp.com/download/attachments/62825785/ClockReferenceConfigurationMultipleClockReference.png" width="800"><br></section>
</div>
</article></article><hr><span style="float: inline-end;"><a href="#">Top</a></span><article class="topic nested0 nobody" aria-labelledby="ariaid-title4" id="topic_title_PRI_BRI_Card_Configuration_d1e18">
<h1 class="title topictitle1" id="ariaid-title4">PRI/BRI Card Configuration</h1>
<article class="topic task nested1" aria-labelledby="ariaid-title5" id="task_p1v_ysc_ww">
<h2 class="title topictitle2" id="ariaid-title5">Associating a PRI Port to a Line Type and Protocol</h2>
<div class="body taskbody">
<section><div class="tasklabel"><strong class="sectiontitle tasklabel">Steps</strong></div><ol class="ol steps"><li class="li step">
<span class="ph cmd">Go to <span class="keyword wintitle">System</span>/<span class="keyword wintitle">Hardware</span>.</span>
</li><li class="li step">
<span class="ph cmd">In the <span class="keyword wintitle">PRI Ports Configuration</span> table,
from the <span class="keyword wintitle">Line Type</span>
selection list, select either E1 or T1.</span>
</li><li class="li step">
<span class="ph cmd">From the <span class="keyword wintitle">Signaling</span>
selection list, associate a type of signaling to the PRI port. </span>
</li><li class="li step">
<span class="ph cmd">Click <span class="keyword wintitle">Apply</span>.</span>
</li><li class="li step">
<span class="ph cmd">Restart the unit.</span>
</li></ol></section>
<section class="section result"><div class="tasklabel"><strong class="sectiontitle tasklabel">Result</strong></div>The selected line type will appear under <span class="keyword wintitle">ISDN</span>/<span class="keyword wintitle">Primary Rate Interface</span>. This is an
example of a PRI port association. <br><img class="image" id="task_p1v_ysc_ww__image_zs2_jcz_zw" src="https://documentation.media5corp.com/download/attachments/62825785/PriPortsConfiguration.PNG" width="800"><br>
</section>
</div>
</article><hr><span style="float: inline-end;"><a href="#">Top</a></span><article class="topic task nested1" aria-labelledby="ariaid-title6" id="unique_18643365261779074839">
<h2 class="title topictitle2" id="ariaid-title6">Associating a BRI Port to a Line Type and Protocol</h2>
<div class="body taskbody">
<section><div class="tasklabel"><strong class="sectiontitle tasklabel">Steps</strong></div><ol class="ol steps"><li class="li step">
<span class="ph cmd">Go to <span class="keyword wintitle">System</span>/<span class="keyword wintitle">Hardware</span>.</span>
</li><li class="li step">
<span class="ph cmd">In the <span class="keyword wintitle">PRI Ports Configuration</span> table,
from the <span class="keyword wintitle">Line Type</span>
selection list, select either E1 or T1.</span>
</li><li class="li step">
<span class="ph cmd">From the <span class="keyword wintitle">Signaling</span>
selection list, associate a type of signaling to the PRI port. </span>
</li><li class="li step">
<span class="ph cmd">Click <span class="keyword wintitle">Apply</span>.</span>
</li></ol></section>
<section class="section result"><div class="tasklabel"><strong class="sectiontitle tasklabel">Result</strong></div>The selected line type will appear under <span class="keyword wintitle">ISDN</span>/<span class="keyword wintitle">Primary Rate Interface</span>. This is an
example of a PRI port association. <br><img class="image" id="unique_18643365261779074839__image_zs2_jcz_zw" src="https://documentation.media5corp.com/download/attachments/62825785/PriPortsConfiguration.PNG" width="800"><br>
</section>
</div>
</article></article><hr><span style="float: inline-end;"><a href="#">Top</a></span><article class="topic nested0 nobody" aria-labelledby="ariaid-title7" id="topic_title_Power_Feeding_d1e21">
<h1 class="title topictitle1" id="ariaid-title7">Power Feeding</h1>
<article class="topic task nested1" aria-labelledby="ariaid-title8" id="task_bkp_2jb_ww">
<h2 class="title topictitle2" id="ariaid-title8">Enabling Power Feeding</h2>
<div class="body taskbody">
<section class="section context"><div class="tasklabel"><strong class="sectiontitle tasklabel">Context</strong></div><div class="note note note_note"><span class="note__title">Note:</span> Your unit
must support Power Feeding.</div></section>
<section><div class="tasklabel"><strong class="sectiontitle tasklabel">Steps</strong></div><ol class="ol steps"><li class="li step">
<span class="ph cmd">Go to <span class="keyword wintitle">System</span>/<span class="keyword wintitle">Hardware</span>.</span>
</li><li class="li step">
<span class="ph cmd">From the <span class="keyword wintitle">BRI Cards Configuration </span> table,
from the <span class="keyword wintitle">Power Feeding</span>
drop down list, select <span class="keyword wintitle">Enable</span>.</span>
</li><li class="li step">
<span class="ph cmd">Click <span class="keyword wintitle">Apply</span>.</span>
</li></ol></section>
<section class="section result"><div class="tasklabel"><strong class="sectiontitle tasklabel">Result</strong></div>Unit will feed power to the selected BRI interface.<br><img class="image" id="task_bkp_2jb_ww__image_csx_mlz_zw" src="https://documentation.media5corp.com/download/attachments/62825785/BRIPortsConfiguration.png" width="800"><br></section>
</div>
</article><hr><span style="float: inline-end;"><a href="#">Top</a></span><article class="topic task nested1" aria-labelledby="ariaid-title9" id="unique_925622820785344014">
<h2 class="title topictitle2" id="ariaid-title9">Disabling Power Feeding</h2>
<div class="body taskbody">
<section class="section context"><div class="tasklabel"><strong class="sectiontitle tasklabel">Context</strong></div><div class="note important note_important"><span class="note__title">IMPORTANT:</span> Your unit must have a BRI card.</div></section>
<section><div class="tasklabel"><strong class="sectiontitle tasklabel">Steps</strong></div><ol class="ol steps"><li class="li step">
<span class="ph cmd">Go to <span class="keyword wintitle">System</span>/<span class="keyword wintitle">Hardware</span>.</span>
</li><li class="li step">
<span class="ph cmd">From the <span class="keyword wintitle">BRI Cards Configuration </span> table,
from the <span class="keyword wintitle">Power Feeding</span>
drop down list, select <span class="keyword wintitle">Disable</span>.</span>
</li><li class="li step">
<span class="ph cmd">Click <span class="keyword wintitle">Apply</span>.</span>
</li></ol></section>
<section class="section result"><div class="tasklabel"><strong class="sectiontitle tasklabel">Result</strong></div>The unit will no longer receive power from the BRI card.<br><img class="image" id="unique_925622820785344014__image_tzc_hsz_zw" src="https://documentation.media5corp.com/download/attachments/62825785/BRIPortsConfiguration.png" width="800"><br></section>
</div>
</article></article><hr><span style="float: inline-end;"><a href="#">Top</a></span><article class="topic nested0 nobody" aria-labelledby="ariaid-title10" id="topic_title_Bridging_d1e24">
<h1 class="title topictitle1" id="ariaid-title10">Bridging</h1>
<article class="topic task nested1" aria-labelledby="ariaid-title11" id="task_uhd_4kb_ww">
<h2 class="title topictitle2" id="ariaid-title11">Bridging two Ethernet Ports</h2>
<div class="body taskbody">
<section class="section context"><div class="tasklabel"><strong class="sectiontitle tasklabel">Context</strong></div><div class="note important note_important"><span class="note__title">IMPORTANT:</span> This feature is not available on Mediatrix Sentinel and Mediatrix G7
units.</div><div class="note important note_important"><span class="note__title">IMPORTANT:</span> Bridging
both Ethernet ports will have a direct impact on your Network Interfaces. All
existing Links will become invalid. Please make sure that your Network Interfaces
are associated with an active link under <span class="keyword wintitle">Network</span>/<span class="keyword wintitle">Interfaces</span>. </div></section>
<section><div class="tasklabel"><strong class="sectiontitle tasklabel">Steps</strong></div><ol class="ol steps"><li class="li step stepexpand">
<span class="ph cmd">Go to <span class="keyword wintitle">System</span>/<span class="keyword wintitle">Hardware</span>.</span>
</li><li class="li step stepexpand">
<span class="ph cmd">In the <span class="keyword wintitle">Unit Configuration</span> table,
select <span class="keyword wintitle">Bridge</span>.</span>
</li><li class="li step stepexpand">
<span class="ph cmd">Click <span class="keyword wintitle">Apply</span>.</span>
<div class="itemgroup info">
<div class="note important note_important"><span class="note__title">IMPORTANT:</span> At this point DO NOT restart the unit just yet. (Even if
the Web interface displays a message to do so). If you restart the unit
before completing the <a class="xref" href="#task_w3c_wrb_ww">Creating the Bridging Interface</a>, you may
loose contact with the unit and need to perform a factory reset. </div>
</div>
</li></ol></section>
<section class="section result"><div class="tasklabel"><strong class="sectiontitle tasklabel">Result</strong></div>A new Link will be created. The name is automatically generated and varies from one
type of unit to another (e.g. eth1-2 or wan-lan). The new link will be available in the
<span class="keyword wintitle">Network Interface Configuration</span> table
(<span class="keyword wintitle">Network</span>/<span class="keyword wintitle">Interfaces</span>).<br><img class="image" id="task_uhd_4kb_ww__image_cds_lfz_zw" src="https://documentation.media5corp.com/download/attachments/62825785/UnitConfigurationBridge.png" width="800"><br></section>
</div>
<nav role="navigation" class="related-links"><div class="linklist relinfo reltasks"><div class="linklistlabel"><strong class="sectiontitle linklistlabel">Next Step</strong></div><ul class="linklist"><li class="linklist"><a class="link" href="#task_w3c_wrb_ww">Creating the Bridging Interface</a></li></ul></div></nav></article><hr><span style="float: inline-end;"><a href="#">Top</a></span><article class="topic task nested1" aria-labelledby="ariaid-title12" id="task_w3c_wrb_ww">
<h2 class="title topictitle2" id="ariaid-title12">Creating the Bridging Interface</h2>
<div class="body taskbody">
<section class="section prereq"><div class="tasklabel"><strong class="sectiontitle tasklabel">Before you begin</strong></div>
<a class="xref" href="#task_uhd_4kb_ww">Bridging two Ethernet Ports</a> must be
completed.</section>
<section class="section context"><div class="tasklabel"><strong class="sectiontitle tasklabel">Context</strong></div><div class="note important note_important"><span class="note__title">IMPORTANT:</span> This feature is only available on units with 2 Ethernet
ports.</div></section>
<section><div class="tasklabel"><strong class="sectiontitle tasklabel">Steps</strong></div><ol class="ol steps"><li class="li step stepexpand">
<span class="ph cmd">Go to <span class="keyword wintitle">Network</span>/<span class="keyword wintitle">Interfaces</span>.</span>
</li><li class="li step stepexpand">
<span class="ph cmd">In the <span class="keyword wintitle">Network Interface Configuration</span> table, enter <span class="keyword wintitle">Temporary</span> in the empty field.</span>
</li><li class="li step stepexpand">
<span class="ph cmd">Click <img class="image" id="task_w3c_wrb_ww__image_dcl_ywb_ww" src="https://documentation.media5corp.com/download/attachments/62825785/Plusbleu.jpg" width="15">. </span>
</li><li class="li step stepexpand">
<span class="ph cmd">Replicate all the settings the <span class="keyword wintitle">Uplink</span> Network Interface has
for the new <span class="keyword wintitle">Temporary</span> Network Interface.</span>
</li><li class="li step stepexpand">
<span class="ph cmd">From the <span class="keyword wintitle">Activation</span>
drop-down menu, select <span class="keyword wintitle">Enable</span> for the
<span class="keyword wintitle">Temporary</span> Network Interface.</span>
</li><li class="li step stepexpand">
<span class="ph cmd">From the <span class="keyword wintitle">Activation</span>
drop-down menu, select <span class="keyword wintitle">Disable</span> for the <span class="keyword wintitle">Lan1</span> Network
Interface.</span>
<div class="itemgroup info">
<div class="note note note_note"><span class="note__title">Note:</span> At this point, a new bridging link is created, either
<span class="keyword wintitle">wan-lan</span> or <span class="keyword wintitle">eth1-2</span> depending on
your unit.</div>
</div>
</li><li class="li step stepexpand">
<span class="ph cmd">For the <span class="keyword wintitle">Uplink</span>
Network Interface, from the <span class="keyword wintitle">Link</span> selection list, choose
the new link created for bridging.</span>
</li><li class="li step stepexpand">
<span class="ph cmd">For the <span class="keyword wintitle">UplinkV6 </span>
Network Interface, from the <span class="keyword wintitle">Link</span> selection list, choose
the new link created for bridging.</span>
</li><li class="li step stepexpand">
<span class="ph cmd">Click <span class="keyword wintitle">Apply</span>.</span>
</li><li class="li step stepexpand">
<span class="ph cmd">Click <span class="keyword wintitle">Restart the Unit</span>,
located at the top of the page.</span>
</li><li class="li step stepexpand">
<span class="ph cmd">When the unit is restarted, go to <span class="keyword wintitle">Network</span>/<span class="keyword wintitle">Interfaces</span>.</span>
</li><li class="li step stepexpand">
<span class="ph cmd">Click - to delete the temporary Network Interface as it is no longer
needed.</span>
</li></ol></section>
<section class="section result"><div class="tasklabel"><strong class="sectiontitle tasklabel">Result</strong></div>
<br><img class="image" id="task_w3c_wrb_ww__image_p4w_q3z_zw" src="https://documentation.media5corp.com/download/attachments/62825785/NetworkInterfaceConfigurationBridge.png" width="800"><br>
</section>
</div>
</article></article><hr><span style="float: inline-end;"><a href="#">Top</a></span><article class="topic reference nested0" aria-labelledby="ariaid-title13" id="reference_gs4_rxw_ww">
<h1 class="title topictitle1" id="ariaid-title13">Hardware Advanced Parameters </h1>
<div class="body refbody"><p class="shortdesc">Some aspects of the Hardware configuration can only be completed with the MIB
parameters. </p>
<section class="section">These parameters can be accessed and configured by:<ul class="ul">
<li class="li">using a MIB browser</li>
<li class="li">using the CLI</li>
<li class="li">creating a configuration script containing the configuration variables</li>
</ul> For the complete list of available parameters, refer to the Hardware section of the
<a class="xref" href="https://documentation.media5corp.com/display/DGWLATEST/Reference+Guide" target="_blank">DGW Configuration Guide - Reference Guide</a> published on the <a class="xref" href="https://documentation.media5corp.com/" target="_blank">Media5 Documentation Portal</a>.</section>
</div>
</article><hr><span style="float: inline-end;"><a href="#">Top</a></span><article class="topic reference nested0" aria-labelledby="ariaid-title14" id="reference_j4g_nbv_gfb">
<h1 class="title topictitle1" id="ariaid-title14">Online Help</h1>
<p class="shortdesc"><span class="ph">If you are not familiar with the meaning of the fields and
buttons, click <span class="keyword wintitle">Show Help</span>, located at the upper right corner of
the Web page. When activated, the fields and buttons that offer online help will
change to green and if you hover over them, the description will bedisplayed.</span></p>
</article><hr><span style="float: inline-end;"><a href="#">Top</a></span><article class="topic concept nested0" aria-labelledby="ariaid-title15" id="concept_v4k_q3h_1r">
<h1 class="title topictitle1" id="ariaid-title15">DGW Documentation</h1>
<div class="body conbody"><p class="shortdesc">Mediatrix devices are supplied with an exhaustive set of documentation. </p>
<p class="p">Mediatrix user documentation is available on the <a class="xref" href="http://documentation.media5corp.com" target="_blank">Media5 Documentation
Portal</a>.</p>
<div class="p">Several types of documents were created to clearly present the information you are looking for.
Our documentation includes:<ul class="ul" id="concept_v4k_q3h_1r__ul_bqy_cjh_1r">
<li class="li"><strong class="ph b">Release notes</strong>: Generated at each GA release, this document includes the known and
solved issues of the software. It also outlines the changes and the new features the release
includes.</li>
<li class="li"><strong class="ph b">Configuration notes</strong>: These documents are created to facilitate the configuration of a
specific use case. They address a configuration aspect we consider that most users will need to
perform. However, in some cases, a configuration note is created after receiving a question
from a customer. They provide standard step-by-step procedures detailing the values of the
parameters to use. They provide a means of validation and present some conceptual information.
The configuration notes are specifically created to guide the user through an aspect of the
configuration. </li>
<li class="li"><strong class="ph b">Technical bulletins</strong>: These documents are created to facilitate the configuration of a
specific technical action, such as performing a firmware upgrade.</li>
<li class="li"><strong class="ph b">Hardware installation guide</strong>: They provide the detailed procedure on how to safely and
adequately install the unit. It provides information on card installation, cable connections,
and how to access for the first time the Management interface.</li>
<li class="li"><strong class="ph b">User guide</strong>: The user guide explains how to customise to your needs the configuration
of the unit. Although this document is task oriented, it provides conceptual information to
help the user understand the purpose and impact of each task. The User Guide will provide
information such as where and how TR-069 can be configured in the Management Interface, how to
set firewalls, or how to use the CLI to configure parameters that are not available in the
Management Interface.</li>
<li class="li"><strong class="ph b">Reference guide</strong>: This exhaustive document has been created for advanced users. It
includes a description of all the parameters used by all the services of the Mediatrix units.
You will find, for example, scripts to configure a specific parameter, notification messages
sent by a service, or an action description used to create Rulesets. This document includes
reference information such as a dictionary, and it does not include any step-by-step
procedures. </li>
</ul></div>
</div>
</article><hr><span style="float: inline-end;"><a href="#">Top</a></span><article class="topic concept nested0" aria-labelledby="ariaid-title16" id="concept_fqm_rv4_k4">
<h1 class="title topictitle1" id="ariaid-title16">Copyright Notice</h1>
<div class="body conbody"><p class="shortdesc">Copyright © 20222023 Media5 Corporation.</p>
<p class="p">This document contains information that is proprietary to Media5 Corporation.</p>
<p class="p">Media5 Corporation reserves all rights to this document as well as to the Intellectual Property
of the document and the technology and know-how that it includes and represents.</p>
<p class="p">This publication cannot be reproduced, neither in whole nor in part, in any form whatsoever,
without written prior approval by Media5 Corporation.</p>
<p class="p">Media5 Corporation reserves the right to revise this publication and make changes at any time
and without the obligation to notify any person and/or entity of such revisions and/or
changes.</p>
</div>
</article></article></main></body></html> |