<html lang="en"><head><meta http-equiv="Content-Type" content="text/html; charset=UTF-8"><meta charset="UTF-8"><meta name="copyright" content="(C) Copyright 2022"><meta name="DC.rights.owner" content="(C) Copyright 2022"><meta name="DC.type" content="topic"><meta name="prodname" content=""><meta name="version" content="DGW 49.0.2809"><meta name="platform" content=""><meta name="DC.date.modified" content="2022-11-10"><meta name="DC.date.issued" content="2022-11-10"><meta name="DC.date.available" content="2022-11-10"><meta name="ChapterNumbering" content="no"><meta name="DC.format" content="HTML5"><meta name="DC.identifier" content="topic_title_Introduction_d1e13"><link href="https://fonts.googleapis.com/css?family=Open+Sans" rel="stylesheet"><link rel="stylesheet" type="text/css" href="https://documentation.media5corp.com/download/attachments/44413839/commonltr.css"><link rel="stylesheet" type="text/css" href="https://documentation.media5corp.com/download/attachments/44413839/custom.css"><title>Delta Document from Mediatrix 4100 to Mediatrix S7 Series</title></head><body class="nobody"><header role="banner"><div class="topicmeta title">Delta Document from Mediatrix 4100 to Mediatrix S7 Series</div><div class="topicmeta date">2022-11-10</div><div class="topicmeta product"></div><div class="topicmeta version">DGW 49.0.2809</div><div class="topicmeta pdf"><a href="https://documentation.media5corp.com/download/attachments/44413839/Delta%20Document%20from%20Mediatrix%204100%20to%20S7%20Series.pdf" rel="nofollow">Download PDF Document</a></div><hr><span style="float: inline-end;"></span></header><nav role="toc"><ul><li><a href="#topic_title_Introduction_d1e13">Introduction</a><ul><li><a href="#concept_bv3_w2k_bbb">Mediatrix S7 Series</a></li><li><a href="#unique_4979455901872344451">Mediatrix S7 LP Series</a></li></ul></li><li><a href="#reference_l3c_shk_bbb">Differences Between the Mediatrix 4116 and Mediatrix S716 </a></li><li><a href="#reference_ygv_qjk_bbb">Differences Between the Mediatrix 4116-4124 and S724 </a></li><li><a href="#reference_j4g_nbv_gfb">Online Help</a></li><li><a href="#concept_v4k_q3h_1r">DGW Documentation</a></li><li><a href="#concept_fqm_rv4_k4">Copyright Notice</a></li></ul></nav><main role="main"><article role="article" aria-labelledby="ariaid-title1"><hr><span style="float: inline-end;"><a href="#">Top</a></span><article class="nested0" aria-labelledby="ariaid-title1" id="topic_title_Introduction_d1e13">
<h1 class="title topictitle1" id="ariaid-title1">Introduction</h1>
<article class="topic concept nested1" aria-labelledby="ariaid-title2" id="concept_bv3_w2k_bbb">
<h2 class="title topictitle2" id="ariaid-title2">Mediatrix S7 Series</h2>
<div class="body conbody"><p class="shortdesc">The Mediatrix S7 Series of analog VoIP adaptors (ATAs) offers the ability to smoothly
connect all IP and legacy equipment to a hosted or on premise IP-PBX.</p>
<p class="p">It is also the ideal solution to connect traditional PBXs and phones to an IP core network
without impacting current customer base. The S7 allows operators and providers to use hybrid
IP and analog telephone systems with a wide variety of cost-effective and easy-to-deploy
applications including multi-tenant buildings, Hosted UC, and survivability for remote
offices. The Mediatrix S7 rich feature set, including outstanding voice quality and mass
management, enables users to fully benefit from the IP communications while preserving
investment on analog phones, faxes, and PBXs. Mediatrix gateway and ATA series are
interoperable with all SIP variants and compliant with most VoIP systems, analog PBXs, and
phones worldwide.</p>
<div class="p">This new series includes the following models:<ul class="ul" id="concept_bv3_w2k_bbb__ul_nww_hy3_dbb">
<li class="li">Mediatrix S716 (16 FXS ports)</li>
<li class="li">Mediatrix S724 (24 FXS ports)</li>
</ul></div>
</div>
</article><hr><span style="float: inline-end;"><a href="#">Top</a></span><article class="topic concept nested1" aria-labelledby="ariaid-title3" id="unique_4979455901872344451">
<h2 class="title topictitle2" id="ariaid-title3">Mediatrix S7 LP Series</h2>
<div class="body conbody"><p class="shortdesc">The Mediatrix S7 LP is the leading ATA to deploy cloud telephony services for demanding
wiring conditions and over-voltage exposure applications. </p>
<p class="p">The Mediatrix S7 LP features long haul FXS ports, lightning protection, outstanding voice
quality, rich telephony functionalities, easy deployment and provisioning, advanced security, and
superior performance. These make the Mediatrix S7 LP the ideal solution for the hospitality
sector, campuses, transport infrastructures, large facilities, and buildings far away from one
another. The Mediatrix gateways and ATAs series are interoperable with all SIP variants and
compliant with most VoIP systems, analog PBXs, and phones worldwide.</p>
<div class="p">This new series includes the following models:<ul class="ul" id="unique_4979455901872344451__ul_nww_hy3_dbb">
<li class="li">Mediatrix S716 LP (16 FXS ports)</li>
<li class="li">Mediatrix S724 LP (24 FXS ports)</li>
</ul></div>
</div>
</article></article><hr><span style="float: inline-end;"><a href="#">Top</a></span><article class="topic reference nested0" aria-labelledby="ariaid-title4" id="reference_l3c_shk_bbb">
<h1 class="title topictitle1" id="ariaid-title4">Differences Between the Mediatrix 4116 and Mediatrix S716 </h1>
<div class="body refbody">
<section class="section">
<p class="p">For more information on the Mediatrix 4104 and 4108 units, please refer to the <a class="xref" href="https://documentation.media5corp.com/display/DGWLATEST/Delta+Document+from+4104+and+4108+to+C7+Series" target="_blank">Delta Document - Delta Document from 4104 and 4108 to C7
Series</a> published on the <a class="xref" href="https://documentation.media5corp.com/" target="_blank">Media5 Documentation Portal</a>.</p>
</section>
<section class="section">
<table class="table frame-all" id="reference_l3c_shk_bbb__table_bvf_b3k_bbb"><caption></caption><colgroup><col><col></colgroup><thead class="thead">
<tr class="row">
<th class="entry colsep-1 rowsep-1" id="reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__1">Mediatrix 4116/LP16</th>
<th class="entry colsep-1 rowsep-1" id="reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__2">Mediatrix S716/S716 LP</th>
</tr>
</thead><tbody class="tbody">
<tr class="row grey">
<td class="entry colsep-1 rowsep-1" headers="reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__1 reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__2" colspan="2">DSP processing capacity and capability</td>
</tr>
<tr class="row">
<td class="entry colsep-1 rowsep-1" headers="reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__1">
<p class="p">G.711 – 16 RTP or SRTP calls</p>
<p class="p">G.726/G.729 – 16 RTP calls or 12 SRTP calls</p>
<p class="p">G.723 – 16 RTP calls or 12 SRTP calls</p>
<p class="p">Maximum of 4x 3-way conference calls</p>
</td>
<td class="entry colsep-1 rowsep-1" headers="reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__2"><p class="p">G.711 – 16 RTP or SRTP calls</p><p class="p">G.726/G.729 – 16 RTP calls or 15 SRTP
calls</p><p class="p">Limited support for G.723</p>Maximum of 2x 3-way conference
calls</td>
</tr>
<tr class="row grey">
<td class="entry colsep-1 rowsep-1" headers="reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__1 reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__2" colspan="2">Visual Message Waiting Indicator (VMWI)</td>
</tr>
<tr class="row">
<td class="entry colsep-1 rowsep-1" headers="reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__1">High voltage signals are supported</td>
<td class="entry colsep-1 rowsep-1" headers="reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__2">High voltage signals are not supported</td>
</tr>
<tr class="row grey">
<td class="entry colsep-1 rowsep-1" headers="reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__1 reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__2" colspan="2">Telephony interfaces</td>
</tr>
<tr class="row">
<td class="entry colsep-1 rowsep-1" headers="reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__1">16 FXS ports - telephony connectors (RJ-11)</td>
<td class="entry colsep-1 rowsep-1" headers="reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__2">
<p class="p">16 FXS ports - telephony connectors (RJ-11)</p>
<p class="p">Optional 24xRJ-11 to RJ-21 cable adapter.</p>
</td>
</tr>
<tr class="row">
<td class="entry colsep-1 rowsep-1" headers="reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__1">FXS numbering from bottom to top, from right to left</td>
<td class="entry colsep-1 rowsep-1" headers="reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__2">FXS numbering from left to right, from top to bottom</td>
</tr>
<tr class="row">
<td class="entry colsep-1 rowsep-1" headers="reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__1">
<p class="p">4116: with bypass interface </p>
<p class="p">LP16: without bypass interface</p>
</td>
<td class="entry colsep-1 rowsep-1" headers="reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__2">Optional bypass interface available</td>
</tr>
<tr class="row grey">
<td class="entry colsep-1 rowsep-1" headers="reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__1 reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__2" colspan="2">Long Loop current limit (min – default - max)
(mA)</td>
</tr>
<tr class="row">
<td class="entry colsep-1 rowsep-1" headers="reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__1">20 - 22 - 25</td>
<td class="entry colsep-1 rowsep-1" headers="reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__2">20 - 30 - 32</td>
</tr>
<tr class="row grey">
<td class="entry colsep-1 rowsep-1" headers="reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__1 reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__2" colspan="2">Network interfaces</td>
</tr>
<tr class="row">
<td class="entry colsep-1 rowsep-1" headers="reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__1">1x or 2x 10/100 Base-T Ethernet interfaces</td>
<td class="entry colsep-1 rowsep-1" headers="reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__2">5x Gigabit Base-T Ethernet interfaces</td>
</tr>
<tr class="row">
<td class="entry colsep-1 rowsep-1" headers="reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__1"></td>
<td class="entry colsep-1 rowsep-1" headers="reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__2">Hardware network switch behind ETH2-5</td>
</tr>
<tr class="row">
<td class="entry colsep-1 rowsep-1" headers="reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__1">Software bridging capability with ETH1 and ETH2</td>
<td class="entry colsep-1 rowsep-1" headers="reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__2">No software bridging capability</td>
</tr>
<tr class="row grey">
<td class="entry colsep-1 rowsep-1" headers="reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__1 reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__2" colspan="2">Other interfaces</td>
</tr>
<tr class="row">
<td class="entry colsep-1 rowsep-1" headers="reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__1">N/A</td>
<td class="entry colsep-1 rowsep-1" headers="reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__2">TDM sync RJ-45 connectors (SYNC IN, SYNC OUT)</td>
</tr>
<tr class="row grey">
<td class="entry colsep-1 rowsep-1" headers="reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__1 reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__2" colspan="2">Physical characteristics</td>
</tr>
<tr class="row">
<td class="entry colsep-1 rowsep-1" headers="reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__1">
<p class="p">Depth: 21 cm</p>
<p class="p">Weight: 1.7kg – 1.8 kg</p>
<p class="p">Plastic casing</p>
</td>
<td class="entry colsep-1 rowsep-1" headers="reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__2">
<p class="p">Depth: 19.5 cm </p>
<p class="p">Weight: 3 kg</p>
<p class="p">Metal casing</p>
</td>
</tr>
<tr class="row grey">
<td class="entry colsep-1 rowsep-1" headers="reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__1 reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__2" colspan="2">Operating temperature</td>
</tr>
<tr class="row">
<td class="entry colsep-1 rowsep-1" headers="reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__1">0°C to 45°C</td>
<td class="entry colsep-1 rowsep-1" headers="reference_l3c_shk_bbb__table_bvf_b3k_bbb__entry__2">0°C to 40°C</td>
</tr>
</tbody></table>
</section>
</div>
</article><hr><span style="float: inline-end;"><a href="#">Top</a></span><article class="topic reference nested0" aria-labelledby="ariaid-title5" id="reference_ygv_qjk_bbb">
<h1 class="title topictitle1" id="ariaid-title5">Differences Between the Mediatrix 4116-4124 and S724 </h1>
<div class="body refbody">
<section class="section">
<table class="table frame-all" id="reference_ygv_qjk_bbb__table_iwg_mkk_bbb"><caption></caption><colgroup><col><col></colgroup><thead class="thead">
<tr class="row">
<th class="entry colsep-1 rowsep-1" id="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__1">Mediatrix 4124/LP24</th>
<th class="entry colsep-1 rowsep-1" id="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__2">Mediatrix S724/S724 LP</th>
</tr>
</thead><tbody class="tbody">
<tr class="row color">
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__1 reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__2" colspan="2">DSP processing capacity and capability</td>
</tr>
<tr class="row">
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__1" rowspan="4">
<p class="p">G.711 – 24 RTP or SRTP calls</p>
<p class="p">G.726/G.729 – 24 RTP calls or 18 SRTP calls</p>
<p class="p">G.723 – 24 RTP calls or 18 SRTP calls</p>
<p class="p">Maximum of 6x 3-way conference calls</p>
</td>
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__2">1 DSP</td>
</tr>
<tr class="row">
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__2">
<p class="p">G.711 – 17 RTP calls or 16 SRTP calls</p>
<p class="p">G.726/G.729 – 16 RTP calls or 15 SRTP calls</p>
<p class="p">Limited support for G.723</p>
<p class="p">Maximum of 2x 3-way conference calls</p>
</td>
</tr>
<tr class="row">
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__2">2 DSPs</td>
</tr>
<tr class="row">
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__2">
<p class="p">G.711 – 24 RTP or SRTP calls </p>
<p class="p">G.726/G.729 – 24 RTP or SRTP calls </p>
<p class="p">Limited support for G.723</p>
<p class="p">Maximum of 4x 3-way conference calls</p>
</td>
</tr>
<tr class="row color">
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__1 reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__2" colspan="2">Visual Message Waiting Indicator (VMWI)</td>
</tr>
<tr class="row">
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__1"> High voltage signals are supported</td>
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__2">High voltage signals are not supported</td>
</tr>
<tr class="row color">
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__1 reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__2" colspan="2">Telephony interfaces</td>
</tr>
<tr class="row">
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__1">
<p class="p">4124 : 25-pair connector (CN50, RJ21) only</p>
<p class="p">LP24 : 24 FXS ports - telephony connectors (RJ-11)</p>
</td>
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__2">
<p class="p">24 FXS ports - telephony connectors (RJ-11)</p>
<p class="p">Optional 24xRJ-11 to RJ-21 cable adapter.</p>
</td>
</tr>
<tr class="row">
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__1">FXS numbering from bottom to top, from right to left</td>
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__2">FXS numbering from left to right, from top to bottom</td>
</tr>
<tr class="row">
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__1">
<p class="p">4124: with bypass interface </p>
<p class="p">LP24: without bypass interface</p>
</td>
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__2">Optional bypass interface available</td>
</tr>
<tr class="row color">
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__1 reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__2" colspan="2">Long Loop current limit (min – default - max)
(mA)</td>
</tr>
<tr class="row">
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__1">20 - 22 - 25</td>
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__2">20 - 30 - 32</td>
</tr>
<tr class="row color">
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__1 reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__2" colspan="2">Network interfaces</td>
</tr>
<tr class="row">
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__1">1x or 2x 10/100 Base-T Ethernet interfaces</td>
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__2">5x Gigabit Base-T Ethernet interfaces</td>
</tr>
<tr class="row">
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__1"></td>
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__2">Hardware network switch behind ETH2-5</td>
</tr>
<tr class="row">
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__1">Software bridging capability with ETH1 and ETH2</td>
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__2">No software bridging capability</td>
</tr>
<tr class="row color">
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__1 reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__2" colspan="2">Other interfaces</td>
</tr>
<tr class="row">
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__1">N/A</td>
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__2">TDM sync RJ-45 connectors (SYNC IN, SYNC OUT)</td>
</tr>
<tr class="row color">
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__1 reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__2" colspan="2">Physical characteristics</td>
</tr>
<tr class="row">
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__1">
<p class="p">Depth: 21 cm</p>
<p class="p">Weight: 1.7kg – 1.8 kg</p>
<p class="p">Plastic casing</p>
</td>
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__2">
<p class="p">Depth: 19.5 cm </p>
<p class="p">Weight: 3 kg</p>
<p class="p">Metal casing</p>
</td>
</tr>
<tr class="row color">
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__1 reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__2" colspan="2">Operating temperature</td>
</tr>
<tr class="row">
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__1">0°C to 45°C</td>
<td class="entry colsep-1 rowsep-1" headers="reference_ygv_qjk_bbb__table_iwg_mkk_bbb__entry__2">0°C to 40°C</td>
</tr>
</tbody></table>
</section>
</div>
</article><hr><span style="float: inline-end;"><a href="#">Top</a></span><article class="topic reference nested0" aria-labelledby="ariaid-title6" id="reference_j4g_nbv_gfb">
<h1 class="title topictitle1" id="ariaid-title6">Online Help</h1>
<p class="shortdesc"><span class="ph">If you are not familiar with the meaning of the fields and
buttons, click <span class="keyword wintitle">Show Help</span>, located at the upper right corner of
the Web page. When activated, the fields and buttons that offer online help will
change to green and if you hover over them, the description will bedisplayed.</span></p>
</article><hr><span style="float: inline-end;"><a href="#">Top</a></span><article class="topic concept nested0" aria-labelledby="ariaid-title7" id="concept_v4k_q3h_1r">
<h1 class="title topictitle1" id="ariaid-title7">DGW Documentation</h1>
<div class="body conbody"><p class="shortdesc">Mediatrix devices are supplied with an exhaustive set of documentation. </p>
<p class="p">Mediatrix user documentation is available on the <a class="xref" href="http://documentation.media5corp.com" target="_blank">Media5 Documentation
Portal</a>.</p>
<div class="p">Several types of documents were created to clearly present the information you are looking for.
Our documentation includes:<ul class="ul" id="concept_v4k_q3h_1r__ul_bqy_cjh_1r">
<li class="li"><strong class="ph b">Release notes</strong>: Generated at each GA release, this document includes the known and
solved issues of the software. It also outlines the changes and the new features the release
includes.</li>
<li class="li"><strong class="ph b">Configuration notes</strong>: These documents are created to facilitate the configuration of a
specific use case. They address a configuration aspect we consider that most users will need to
perform. However, in some cases, a configuration note is created after receiving a question
from a customer. They provide standard step-by-step procedures detailing the values of the
parameters to use. They provide a means of validation and present some conceptual information.
The configuration notes are specifically created to guide the user through an aspect of the
configuration. </li>
<li class="li"><strong class="ph b">Technical bulletins</strong>: These documents are created to facilitate the configuration of a
specific technical action, such as performing a firmware upgrade.</li>
<li class="li"><strong class="ph b">Hardware installation guide</strong>: They provide the detailed procedure on how to safely and
adequately install the unit. It provides information on card installation, cable connections,
and how to access for the first time the Management interface.</li>
<li class="li"><strong class="ph b">User guide</strong>: The user guide explains how to customise to your needs the configuration
of the unit. Although this document is task oriented, it provides conceptual information to
help the user understand the purpose and impact of each task. The User Guide will provide
information such as where and how TR-069 can be configured in the Management Interface, how to
set firewalls, or how to use the CLI to configure parameters that are not available in the
Management Interface.</li>
<li class="li"><strong class="ph b">Reference guide</strong>: This exhaustive document has been created for advanced users. It
includes a description of all the parameters used by all the services of the Mediatrix units.
You will find, for example, scripts to configure a specific parameter, notification messages
sent by a service, or an action description used to create Rulesets. This document includes
reference information such as a dictionary, and it does not include any step-by-step
procedures. </li>
</ul></div>
</div>
</article><hr><span style="float: inline-end;"><a href="#">Top</a></span><article class="topic concept nested0" aria-labelledby="ariaid-title8" id="concept_fqm_rv4_k4">
<h1 class="title topictitle1" id="ariaid-title8">Copyright Notice</h1>
<div class="body conbody"><p class="shortdesc">Copyright © 2022 Media5 Corporation.</p>
<p class="p">This document contains information that is proprietary to Media5 Corporation.</p>
<p class="p">Media5 Corporation reserves all rights to this document as well as to the Intellectual Property
of the document and the technology and know-how that it includes and represents.</p>
<p class="p">This publication cannot be reproduced, neither in whole nor in part, in any form whatsoever,
without written prior approval by Media5 Corporation.</p>
<p class="p">Media5 Corporation reserves the right to revise this publication and make changes at any time
and without the obligation to notify any person and/or entity of such revisions and/or
changes.</p>
</div>
</article></article></main></body></html> |